久久一区二区中文字幕不卡,国产人碰人摸人爱视频,97se亚洲综合,国产精品卫校害羞小美女

High quality hydraulic equipment manufacturers!
TELL:+8613184968882

tilting furnace hydraulic cylinder Sold to Slovakia

Release time:2023-11-08 08:12:07 Hits: Current position: Home > News

This article mainly introduces:

Slovakia hydraulic cylinder,tilting furnace hydraulic cylinder manufacturer,tilting furnace hydraulic cylinder

Slovakia tilting furnace hydraulic cylinder

(Slovakia tilting furnace hydraulic cylinder,produced by Hebei Hengyu company)

tilting furnace hydraulic cylinder are widely used in Slovakia,because of powerful torque,clever hydraulic energy conversion,simple structure and reliable operation.So our company has designed tilting furnace hydraulic cylinder for customers from Slovakia.

Introduction to tilting furnace hydraulic cylinder:

The definition of the minimum starting pressure of the tilting furnace hydraulic cylinder refers to the minimum working pressure of the tilting furnace hydraulic cylinder in the no-load state, which is a comprehensive index reflecting the manufacturing and assembly accuracy of the tilting furnace hydraulic cylinder parts and the size of the sealing friction.

When the tilting furnace hydraulic cylinder needs to be disassembled for maintenance due to leakage and other faults, the piston should be moved to the bottom position of the tilting furnace hydraulic cylinder, and hard beating and sudden drop are strictly prohibited during disassembly.

The meaning of the tilting furnace hydraulic cylinder model marked by the tilting furnace hydraulic cylinder manufacturer: for example, 160/100-1150, its meaning: from a professional point of view, 160 refers to the tilting furnace hydraulic cylinder diameter, which is 160mm, and the 100 behind refers to the rod diameter, which is 100mm. The 1150 refers to the tilting furnace hydraulic cylinder stroke, which is 1150mm. Therefore, on this point, we should have a correct understanding and can not make mistakes.

If air enters the hydraulic system, the tilting furnace hydraulic cylinder will not operate normally, mainly because there is a leak in the system. At this time, check the liquid level of the hydraulic tank, the seals and fittings on the oil suction side of the hydraulic pump, and whether the oil suction filter is too dirty. If so, the hydraulic oil should be replenished, seals and fittings should be treated, and the coarse filter element should be cleaned or replaced.

Answers to some questions about tilting furnace hydraulic cylinder:

What are the reasons why the hydraulic cylinder action is slower than normal?
There are many factors that cause this problem. First, measure the pressure of the main system to see whether the pressure of the main system under the pressure state is consistent with the initial setting. Before measuring the pressure, it is best to check the hydraulic oil and suction oil filter and replace or clean it. Second, check the main relief valve of the reversing control multiway valve to see if there is damage or foreign matter blocking, and clean it. If your pump is a gear pump, the problem should generally be small. Second, look at traffic. There is no leakage in the cylinder, leakage in the reversing valve spool and so on.

What's a minus 40 cylinder made of?
Construction with 1Cr18Ni9Ti, in low temperature conditions impact and tensile strength are very good, can withstand -100 degrees of low temperature, corrosion resistance, material price is not very high, more economic.